Water Heater Safety Advice

Posted by on Dec 3, 2013 in Water Heater Repair Plano, Water Heater Use and Care | 0 comments

Appropriately maintaining ones water heater is important not so it works to its full potential and can conserve some energy cash, however for security issues too. Yes, it can explode – it does not occur too frequently for homeowners, but undoubtedly this is something that Water Heater Repair Plano does not wish to have take place to you!

Vents
Venting can be sort of technical but we will go over the basics below. The vent ought to be the same diameter as the draft diverter of the water heater tank. It is expected to increase and out (for atmospherically vented heaters). Not other directs like up, down, up and out. For direct-vent water heaters, the vent ought to head out a side wall. When it comes to power-vent heaters, the fan blows the fumes out, so there is some versatility in the direction they are vented.

Any roofing system or wall that the vent goes through should be a double wall. The single wall pass throughs need to be screwed with three screws per section. If these fundamentals are not abided by, the vents can break down with time and carbon monoxide can cause significant issues within ones house. Naturally we don’t desire that to occur!

The only other interested in ventilation is that of backdrafting. The fumes can consume the vents with acid condensation. If enough of this gets on cold piping and the water heater it will not be a great circumstance for a properly working water heater. If the fumes return inside the rather of being effectively vented outside, the fumes can get in the living areas of the home. Soot problems can develop too.

Dielectric Connectors
The steel water heater is linked to cooper pipes by the dielectric connectors. When 2 these 2 metals are assembled in water electrolysis happens. The process wears away one metal away to safeguard the other. This procedure is crucial in shielding the inside of the water heater. Inspection for leaks ought to be done where the connections are made.

Temperature and Pressure Relief Valve
This is kinda of a vital part of the water heater, for it helps ensure the darn thing does not explode under pressure if the temperature level goes beyond the appropriate limitations the water heater is created for. Once a year (at least) the T&P valve must be checked to ensure, it is working effectively, for they can be vulnerable to failure. Simply pulling up on the handle water ought to stream freely out and stop when the handle is released. If it just runs or trickles, or does nothing at all, it will need to be replaced.

The drain lines for the T&P line should not be routed up, because water does not flow uphill too well. Make sure it goes down and or out please. If water is running out the drain line routinely, it is the indication of something wrong too. It might be one of numerous different things that we will not enter here – simply call a regional plumbing technician please.

Earthquake Straps
Yep, even if you don’t stay in an earthquake area and are needed to have these on ones water heater, it is a pretty good concept to do so. It appears like a lot of all brand-new homes in sub-divisions nowadays have the water heater in the garage. Yes, there is generally a concrete curb in front of it so one does not drive a vehicle into it, however things can accidentally knock it over so be safe and strap that say thanks to in.

Temperature Level Setting
It appears most residential water heater tanks have settings of warm – hot – very hot … and not degree markings. Some “tips” on conserving energy at home particularly in the winter season time, state to lower the setting on the tank to 120 degrees. That’s fantastic for saving energy however legionella bacteria, which causes Legionnaire’s illness can expand at 120 degrees. By inhaling the mist from the water in the shower, one can inhale the germs. Try to find a medium in between 130 and 120 degrees. Above 130 degrees is technically a scalding temperature level so beware.

Anode Rods
These normally are made of aluminum and there is nothing wrong with that in theory, though we recommend using magnesium ones. Let’s state for whatever reason there is some kind of emergency or disaster where one lives and one needed to use the water in the water heater for drinking water (since bunches of emergency preparedness people suggest doing this). The water that comes out of the drain valve is the water at the bottom of the tank. If one has aluminum anodes, that water will be loaded with aluminum substances, which is bad for the human body. It is bad for the stomach, intestinal tract and joints.

The anodes help with rust defense and are essential in extending the life of the water heater. They can also aid with odor troubles with the water. Overall, magnesium anodes just work much better for a great deal of various reasons like the health perks, let develop up of sediment, a quieter water heater, and they have the tendency to work much better with softened water.

Drain Valve
Okay, just inspect it at least once a year to make sure the darn thing opens and works. And it is excellent to drain and flush the tank at least once a year anyhow (something you of course are doing already). If for some reason one needs to make use of the water throughout a catastrophe or drain it to rather a noisy tank and have actually not drained it routinely, and it doesn’t open, it will take longer to fix the issue you are initially attempting to fix.

Combustion Changer Hatch
Given that gas and oil water heaters breathe the air sucked in from beneath, combust with it and exhale it, it is essential to keep the location around it, specifically beneath the water heater, clean and swept. If if is not burning effectively, it can trigger preparing issues (pointed out above), as well as combustion and fume problems and potentially be a fire risk. Some of examining the chamber and how the flame burns is objective so we are not going to go into a bunch of detail below. it is necessary to see if the combustion chamber roof has a great deal of rust or water markings or is black in color. These are not an excellent sign at all. One ought to see some blue flame at the bottom when it burns and orange and yellow at the top, however, the yellow need to not be incredibly high up. One ought to see gray metal, some white condensation marks are okay.

Water Heater Repair Plano has put together an infographic to highlight the information above:

Water Heater Repair Plano

Check even more water heater maintenance tips here.